Bench Meterman BDM40 Návod k obsluze Strana 1

Procházejte online nebo si stáhněte Návod k obsluze pro Multimetry Bench Meterman BDM40. Bench Meterman BDM40 Operator`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Model BDM40

Bench Digital MultimeterOperator’s Manual Model BDM40 Bench Digital Multimeter

Strany 2 - Symbols Used in this Manual

9 The light grey area around the ACV / DCV switch is extended up and to the right to enclose the five range values of the voltage function. Push the

Strany 3 - TABLE OF CONTENTS

10 PEAK VOLTAGES METERED VOLTAGEAC COMPONENT ONLYAC COUPLEDINPUT WAVEFORMPK -PK0 - PKRMS CALACTRUE RMSDCCOMPONENTONLYDC AND ACTOTAL RMSTRUE RMS =ac

Strany 4

11 Circuit loading error Connecting most voltmeters to a circuit may change the operating voltage of the circuit if it loads the circuit down. As lon

Strany 5 - AC 1000V

12 100.16 = 100.04 = = 10.01 mV = 10.00 mV The error will be about 0.01mV the

Strany 6

13 Maximum current error due to Burden Voltage BESEBE x 100% in−= BESEMIBE x100 Ampsmilli in−−= Examples: Es = 14V, RL = 9Ω, IM = 1497.mA, 0.749V

Strany 7

14 CALIBRATION WARNING THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO AVOID ELECTRICAL SHOCK, DO NOT PERFORM ANY SERVIC

Strany 8 - Slew rate

15 4. Turn the instrument upside down as viewed from the front panel. 5. All adjustments necessary to complete the calibration procedure are now a

Strany 9 - Linear Voltage Measurements

16 Table 4. Display Test SELECT RANGE DISPLAY 200Ω 00.00* 2kΩ .0000* 20kΩ 0.000 200kΩ 00.00 2000kΩ 000.0 20MΩ 0.000 *The least significant

Strany 10 - WARNING

17 Current Test Use the following procedure to verify proper operation of both the AC and DC mA measurement functions: 1. Select DC mA, 200µA r

Strany 11

18 DC Voltage Calibration On the UUT select DC V, 2V range, and connect the calibrator HI volts output to the V-Ω terminal and the calibrator LO volt

Strany 12 - AC Voltage Measurements

1 LIMITED WARRANTY AND LIMITATION OF LIABILITY Your Meterman product will be free from defects in material and workmanship for 90 days from the date

Strany 13 -

19 MAINTENANCE Changing Input Power Configuration This meter was shipped with power cords and fuses for 117V (USA) and 230V (European) operation.

Strany 14 - DIODE MEASUREMENT

20 Non-Warranty Repairs and Replacement – US and Canada Non-warranty repairs in the United States and Canada should be sent to a Meterman Test Tools S

Strany 15 - CALIBRATION

21 ELECTRICAL: The electrical specifications apply for an operating temperature of 18°C to 28°C (64.4°F to 82.4°F), relative humidity up to 90%, and

Strany 16

22 * * Typically 3 to 5 digits of drift will be observed at full scale at 20Hz. Crest Factor Range: Waveforms with a Peak / RMS ratio of 1 :1 to 3:

Strany 17 - Linear Voltage Test

Manual Revision C 09/03 Manual Part Number 1566418 Information contained in this manual is proprietary to Meterman Test Tools and is pro

Strany 18

2 NLE FOR UNITED KINGDOM ONLY NOTE: This lead/appliance must only be wired by competent persons WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT:

Strany 19

3 INTRODUCTION This instrument is a line powered, bench-type digital multimeter with a 4-1/2 digit LED display. The DMM can measure AC/DC volts, AC

Strany 20 - MAINTENANCE

4 The LED Display The high-contrast 4-1/2 digit LED display is easily read from across the room. It can register from 0000 to 19999 counts. For ease

Strany 21 - SPECIFICATIONS

5 OPERATING GUIDELINES INTRODUCTION To use your multimeter fully, there are some additional factors to be considered, such as measurement tech

Strany 22

6 MEASUREMENT TECHNIQUES The information provided here describes techniques In measurement and interpretation of measurements that may extend the

Strany 23

7 Your instrument has a crest factor range of 1.0 to 3.0 at full scale. Going down from full-scale, the crest factor capability increases from 3.0 to:

Strany 24

8 the rise and fall time equals the slew rate of 1.75 µsec. To do this we will calculate the values for the theoretical signal with zero rise and fal

Komentáře k této Příručce

Žádné komentáře